Secondary contamination

On-scene decon

Most contamination can be removed right after the fire, before the soot dries and before anyone takes it into the cab.

The ideal model: wash the firefighter right at the exit from the fire

It works best when a firefighter comes out of the fire and is washed down completely straight away, still wearing breathing apparatus. A colleague rinses them with water, washes them with detergent and a brush and rinses again, from top to bottom. Because the firefighter is still breathing from the apparatus, they do not inhale the soot and dust released during washing. The mask comes off and the gear is removed only after the surface of the PPE is clean.

In our conditions, from spring to autumn. In the Czech Republic, wet decon right at the scene is realistically usable roughly from spring to autumn. In winter, a wet firefighter can get chilled and water and gear can freeze. Then it is important at least to get the gear off quickly into bags, wash the neck, face and hands, and move into the warm and to a shower as soon as possible. Field experience

Before leaving

What to do before leaving. Do gross decon of the gear on scene, take off the PPE and wash your neck, face and hands. Ride in clean spare clothes, with gear in sealed bags outside the cab. Ventilate while driving, set the ventilation to fresh air rather than recirculation, and do not eat or drink until your hands are washed. Wipe down the cab regularly after fires. Expert judgement

How to clean gear on scene

The type of cleaning matters. Blowing with air doesn't help, a dry brush only a little.

How much PAH is removed from gear by cleaning methodreduction of PAHs on turnout gear, more is better
Wet decon with soap−85 %
Dry brush−23 %
Air blowing≈ 0 %

Fent et al., 2017 · gross decon on scene after controlled fires

What follows after returning is described on the Station decon page.